Technical specifications

Number of digital outputs2
Width68mm
Height270mm
With control elementYes
Number of digital inputs6
Depth237mm
Number of analogue outputs1
Number of analogue inputs3
Supporting protocol for LONNo
Number of HW-interfaces USB0
Supporting protocol for ASINo
Supporting protocol for other bus systemsYes
Number of HW-interfaces industrial Ethernet1
Supporting protocol for PROFIBUSYes
Supporting protocol for DeviceNetYes
Supporting protocol for ModbusYes
Number of HW-interfaces RS-4220
Mains voltage208 - 480V
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-4851
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for CANYes
Number of HW-interfaces serial TTY0
With PC connectionYes
Degree of protection (IP)IP20
Supporting protocol for INTERBUSNo
Supporting protocol for SERCOSNo
Number of HW-interfaces RS-2320
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for KNXNo
With optical interfaceNo
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Number of phases outputOther
Max. output at linear load at rated output voltage0.9kW
Application in industrial area permittedYes
Supporting protocol for PROFINET CBANo
Relative symmetric net frequency tolerance5%
Supporting protocol for AS-Interface Safety at WorkNo
Integrated breaking resistanceNo
Supporting protocol for PROFINET IOYes
Max. output frequency8Hz
Number of phases input3
Supporting protocol for EtherNet/IPYes
Nominal output current I2N3A
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Application in domestic- and commercial area permittedYes
Number of interfaces PROFINET0
Max. output voltage230V
Type of converterOther
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFIsafeNo
Max. output at quadratic load at rated output voltage0.9kW
Mains frequency50/60 Hz
4-quadrant operation possibleNo
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LXM32MD12N4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital outputs

2

Width

68mm

Height

270mm

With control element

Number of digital inputs

6

Depth

237mm

Number of analogue outputs

1

Number of analogue inputs

3

Supporting protocol for LON

Number of HW-interfaces USB

0

Supporting protocol for ASI

Supporting protocol for other bus systems

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Number of HW-interfaces RS-422

0

Mains voltage

208 .. 480V

Supporting protocol for TCP/IP

Number of HW-interfaces RS-485

1

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for CAN

Number of HW-interfaces serial TTY

0

With PC connection

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS

Supporting protocol for SERCOS

Number of HW-interfaces RS-232

0

Supporting protocol for INTERBUS-Safety

Supporting protocol for KNX

With optical interface

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Number of phases output

Other

Max. output at linear load at rated output voltage

0.9kW

Application in industrial area permitted

Supporting protocol for PROFINET CBA

Relative symmetric net frequency tolerance

5%

Supporting protocol for AS-Interface Safety at Work

Integrated breaking resistance

Supporting protocol for PROFINET IO

Max. output frequency

8Hz

Number of phases input

3

Supporting protocol for EtherNet/IP

Nominal output current I2N

3A

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Application in domestic- and commercial area permitted

Number of interfaces PROFINET

0

Max. output voltage

230V

Type of converter

Other

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFIsafe

Max. output at quadratic load at rated output voltage

0.9kW

Mains frequency

50/60 Hz

4-quadrant operation possible