Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces serial TTY0
Number of HW-interfaces industrial Ethernet0
With control elementNo
Supporting protocol for LONNo
Number of digital outputs2
Number of digital inputs6
Number of HW-interfaces RS-4850
Depth237mm
Number of HW-interfaces RS-4220
Width68mm
Height270mm
Number of HW-interfaces RS-2320
Number of analogue outputs1
Number of analogue inputs3
Number of HW-interfaces USB0
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusNo
With PC connectionNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Number of interfaces PROFINET0
Supporting protocol for Data-HighwayNo
Type of converterOther
Supporting protocol for SUCONETNo
Integrated breaking resistanceNo
Number of phases input1
Degree of protection (IP)Other
Number of phases output1
Supporting protocol for KNXNo
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsNo
Application in industrial area permittedYes
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleNo
Supporting protocol for DeviceNetNo
Mains voltage115 - 230V
Mains frequency50/60 Hz
Relative symmetric net voltage tolerance10%
Application in domestic- and commercial area permittedNo
Max. output at linear load at rated output voltage1.6kW
Max. output at quadratic load at rated output voltage1.6kW
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Max. output frequency8Hz
Supporting protocol for PROFINET IONo
Supporting protocol for BACnetNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance5%
Nominal output current I2N10A
Max. output voltage230V
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LXM32MD30M2 | Servo Pogon LXM32 Modular 30A 1P 230V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces serial TTY

0

Number of HW-interfaces industrial Ethernet

0

With control element

Supporting protocol for LON

Number of digital outputs

2

Number of digital inputs

6

Number of HW-interfaces RS-485

0

Depth

237mm

Number of HW-interfaces RS-422

0

Width

68mm

Height

270mm

Number of HW-interfaces RS-232

0

Number of analogue outputs

1

Number of analogue inputs

3

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for PROFIBUS

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for Modbus

With PC connection

Supporting protocol for CAN

Supporting protocol for INTERBUS

Number of interfaces PROFINET

0

Supporting protocol for Data-Highway

Type of converter

Other

Supporting protocol for SUCONET

Integrated breaking resistance

Number of phases input

1

Degree of protection (IP)

Other

Number of phases output

1

Supporting protocol for KNX

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Application in industrial area permitted

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Supporting protocol for DeviceNet

Mains voltage

115 .. 230V

Mains frequency

50/60 Hz

Relative symmetric net voltage tolerance

10%

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

1.6kW

Max. output at quadratic load at rated output voltage

1.6kW

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Max. output frequency

8Hz

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

5%

Nominal output current I2N

10A

Max. output voltage

230V

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.