Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of analogue inputs3
Width68mm
Depth237mm
Number of HW-interfaces RS-2320
Number of digital inputs6
With control elementYes
Number of digital outputs2
Supporting protocol for LONNo
Height270mm
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet1
With optical interfaceNo
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSYes
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4851
Number of HW-interfaces other0
Number of HW-interfaces RS-4220
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for CANYes
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Degree of protection (IP)IP20
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetYes
Mains frequency50/60 Hz
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
4-quadrant operation possibleNo
With PC connectionYes
Mains voltage115 - 230V
Application in industrial area permittedYes
Number of interfaces PROFINET0
Type of converterOther
Application in domestic- and commercial area permittedYes
Max. output frequency8Hz
Number of phases input1
Integrated breaking resistanceNo
Max. output at quadratic load at rated output voltage0.3kW
Max. output at linear load at rated output voltage0.3kW
Number of phases outputOther
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance5%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Max. output voltage230V
Supporting protocol for SafetyBUS pNo
Nominal output current I2N1.5A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LXM32MU45M2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of analogue inputs

3

Width

68mm

Depth

237mm

Number of HW-interfaces RS-232

0

Number of digital inputs

6

With control element

Number of digital outputs

2

Supporting protocol for LON

Height

270mm

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

1

With optical interface

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces other

0

Number of HW-interfaces RS-422

0

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for CAN

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

4-quadrant operation possible

With PC connection

Mains voltage

115 .. 230V

Application in industrial area permitted

Number of interfaces PROFINET

0

Type of converter

Other

Application in domestic- and commercial area permitted

Max. output frequency

8Hz

Number of phases input

1

Integrated breaking resistance

Max. output at quadratic load at rated output voltage

0.3kW

Max. output at linear load at rated output voltage

0.3kW

Number of phases output

Other

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

5%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Max. output voltage

230V

Supporting protocol for SafetyBUS p

Nominal output current I2N

1.5A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.