Details
- •Low-voltage industrial components
- •Motor starter/Motor starter combination
- •1 KOM
- •SCHNEIDER
Technical specifications
LZ1H2X43BD | Motorski Pok. Dir. 0,18-2,4A 24VDC

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Depth
113.4mm
Number of auxiliary contacts as normally open contact
0
Rated operation current Ie
2.4A
Overload release current setting
0.18 .. 2.4A
Supporting protocol for INTERBUS
Height
107.5mm
Supporting protocol for PROFIBUS
Supporting protocol for DeviceNet
Supporting protocol for LON
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for TCP/IP
Suitable for emergency stop
Supporting protocol for Data-Highway
With transformer
Supporting protocol for SUCONET
Supporting protocol for CAN
Supporting protocol for other bus systems
Width
22.6mm
Rated operation power at AC-3, 400 V
0.75kW
Number of command positions
0
External reset possible
Number of indicator lights
3
Rail mounting possible
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for PROFINET CBA
With fuse
Rated control supply voltage Us at AC 60HZ
- .. -V
Supporting protocol for EtherNet/IP
With short-circuit release
Supporting protocol for INTERBUS-Safety
Type of electrical connection of main circuit
Spring clamp connection
Supporting protocol for PROFINET IO
Release class
CLASS 10
Rated control supply voltage Us at AC 50HZ
- .. -V
Degree of protection (IP)
IP20
Supporting protocol for DeviceNet Safety
Supporting protocol for SERCOS
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Voltage type for actuating
DC
Type of motor starter
Direct online starter (DOL)
Rated operation current at AC-3, 400 V
2.4A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Temperature compensated overload protection
Ambient temperature, upper operating limit
70°C
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Rated conditional short-circuit current, type 2, 400 V
-A