Technical specifications

Depth113.4mm
Number of auxiliary contacts as normally open contact0
Rated operation current Ie2.4A
Overload release current setting0.18 - 2.4A
Supporting protocol for INTERBUSNo
Height107.5mm
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for LONNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for ASINo
Supporting protocol for ModbusNo
Supporting protocol for TCP/IPNo
Suitable for emergency stopNo
Supporting protocol for Data-HighwayNo
With transformerNo
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Supporting protocol for other bus systemsNo
Width22.6mm
Rated operation power at AC-3, 400 V0.75kW
Number of command positions0
External reset possibleYes
Number of indicator lights3
Rail mounting possibleYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for PROFINET CBANo
With fuseNo
Rated control supply voltage Us at AC 60HZ- - -V
Supporting protocol for EtherNet/IPNo
With short-circuit releaseNo
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for PROFINET IONo
Release classCLASS 10
Rated control supply voltage Us at AC 50HZ- - -V
Degree of protection (IP)IP20
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SERCOSNo
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Rated power, 460 V, 60 Hz, 3-phase0.75kW
Voltage type for actuatingDC
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V2.4A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit70°C
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 2, 230 V-A
Rated conditional short-circuit current, type 2, 400 V-A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LZ1H2X43BD | Motorski Pok. Dir. 0,18-2,4A 24VDC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

113.4mm

Number of auxiliary contacts as normally open contact

0

Rated operation current Ie

2.4A

Overload release current setting

0.18 .. 2.4A

Supporting protocol for INTERBUS

Height

107.5mm

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Supporting protocol for LON

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Suitable for emergency stop

Supporting protocol for Data-Highway

With transformer

Supporting protocol for SUCONET

Supporting protocol for CAN

Supporting protocol for other bus systems

Width

22.6mm

Rated operation power at AC-3, 400 V

0.75kW

Number of command positions

0

External reset possible

Number of indicator lights

3

Rail mounting possible

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for PROFINET CBA

With fuse

Rated control supply voltage Us at AC 60HZ

- .. -V

Supporting protocol for EtherNet/IP

With short-circuit release

Supporting protocol for INTERBUS-Safety

Type of electrical connection of main circuit

Spring clamp connection

Supporting protocol for PROFINET IO

Release class

CLASS 10

Rated control supply voltage Us at AC 50HZ

- .. -V

Degree of protection (IP)

IP20

Supporting protocol for DeviceNet Safety

Supporting protocol for SERCOS

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Rated power, 460 V, 60 Hz, 3-phase

0.75kW

Voltage type for actuating

DC

Type of motor starter

Direct online starter (DOL)

Rated operation current at AC-3, 400 V

2.4A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Temperature compensated overload protection

Ambient temperature, upper operating limit

70°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated conditional short-circuit current, type 2, 400 V

-A