Technical specifications
LZ1H2X4BD | Motorski Pok. Dir. 0,18-2,4A 24VDC

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Height
106.5mm
Width
22.6mm
Number of command positions
0
With transformer
Suitable for emergency stop
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated operation power at AC-3, 400 V
0.75kW
Depth
113.4mm
Supporting protocol for LON
Number of indicator lights
3
Supporting protocol for TCP/IP
Overload release current setting
0.18 .. 2.4A
Supporting protocol for other bus systems
Supporting protocol for Modbus
Supporting protocol for PROFIBUS
Supporting protocol for SUCONET
Rail mounting possible
Supporting protocol for INTERBUS
Rated control supply voltage Us at AC 60HZ
- .. -V
Supporting protocol for CAN
External reset possible
Supporting protocol for ASI
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated operation current Ie
2.4A
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
With short-circuit release
Release class
CLASS 10
Supporting protocol for INTERBUS-Safety
With fuse
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for SERCOS
Type of motor starter
Direct online starter (DOL)
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Rated power, 575 V, 60 Hz, 3-phase
-kW
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Ambient temperature, upper operating limit
70°C
Type of electrical connection of main circuit
Screw connection
Voltage type for actuating
DC
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Supporting protocol for PROFINET CBA
Rated operation current at AC-3, 400 V
2.4A
Temperature compensated overload protection
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Supporting protocol for SafetyBUS p
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for PROFIsafe
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 400 V
-A