Number of command positions0
Height107.5mm
Width22.6mm
With transformerNo
Rated operation power at AC-3, 400 V0.75kW
Depth113.4mm
Number of auxiliary contacts as normally open contact0
Suitable for emergency stopNo
Overload release current setting0.18 - 2.4A
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Supporting protocol for ModbusNo
Supporting protocol for LONNo
Number of auxiliary contacts as normally closed contact0
External reset possibleYes
Supporting protocol for PROFIBUSNo
Rail mounting possibleYes
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Supporting protocol for other bus systemsNo
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ- - -V
Rated operation current Ie2.4A
Number of indicator lights4
Rated control supply voltage Us at AC 50HZ- - -V
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUS-SafetyNo
Release classCLASS 10
With short-circuit releaseNo
Supporting protocol for SafetyBUS pNo
With fuseNo
Ambient temperature, upper operating limit70°C
Rated conditional short-circuit current, type 2, 400 V-A
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Rated power, 460 V, 60 Hz, 3-phase0.75kW
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Supporting protocol for PROFINET CBANo
Type of motor starterReversing starter
Rated power, 575 V, 60 Hz, 3-phase-kW
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for EtherNet/IPNo
Voltage type for actuatingDC
Rated operation current at AC-3, 400 V2.4A
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Supporting protocol for DeviceNet SafetyNo
Temperature compensated overload protectionYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 2, 230 V-A
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LZ2H2X43BD | Motorski Pok. Reverz. 0,18-2,4A 24VDC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of command positions

0

Height

107.5mm

Width

22.6mm

With transformer

Rated operation power at AC-3, 400 V

0.75kW

Depth

113.4mm

Number of auxiliary contacts as normally open contact

0

Suitable for emergency stop

Overload release current setting

0.18 .. 2.4A

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Supporting protocol for Modbus

Supporting protocol for LON

Number of auxiliary contacts as normally closed contact

0

External reset possible

Supporting protocol for PROFIBUS

Rail mounting possible

Supporting protocol for SUCONET

Supporting protocol for CAN

Supporting protocol for other bus systems

Supporting protocol for INTERBUS

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated operation current Ie

2.4A

Number of indicator lights

4

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

Release class

CLASS 10

With short-circuit release

Supporting protocol for SafetyBUS p

With fuse

Ambient temperature, upper operating limit

70°C

Rated conditional short-circuit current, type 2, 400 V

-A

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Rated power, 460 V, 60 Hz, 3-phase

0.75kW

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Supporting protocol for PROFINET CBA

Type of motor starter

Reversing starter

Rated power, 575 V, 60 Hz, 3-phase

-kW

Type of electrical connection of main circuit

Spring clamp connection

Supporting protocol for EtherNet/IP

Voltage type for actuating

DC

Rated operation current at AC-3, 400 V

2.4A

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Supporting protocol for DeviceNet Safety

Temperature compensated overload protection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A