Details
- •Low-voltage industrial components
- •Motor starter/Motor starter combination
- •1 KOM
- •SCHNEIDER
Technical specifications
LZ2H2X43FU | Motorski Pok. Reverz. 0,18-2,4A 230VAC

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Depth
113.4mm
Rated operation power at AC-3, 400 V
0.75kW
Height
107.5mm
With transformer
Width
22.6mm
Number of command positions
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
0.18 .. 2.4A
Number of indicator lights
4
Rated operation current Ie
2.4A
Suitable for emergency stop
Supporting protocol for PROFIBUS
Supporting protocol for DeviceNet
Rail mounting possible
Supporting protocol for TCP/IP
With fuse
Supporting protocol for LON
Supporting protocol for SUCONET
Release class
CLASS 10
Rated control supply voltage Us at AC 60HZ
110 .. 230V
Supporting protocol for SERCOS
Degree of protection (IP)
IP20
Supporting protocol for other bus systems
Supporting protocol for Modbus
Supporting protocol for CAN
Supporting protocol for INTERBUS-Safety
Rated control supply voltage Us at DC
- .. -V
External reset possible
Supporting protocol for AS-Interface Safety at Work
Type of electrical connection of main circuit
Spring clamp connection
Rated control supply voltage Us at AC 50HZ
110 .. 230V
Supporting protocol for Data-Highway
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
With short-circuit release
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for EtherNet/IP
Supporting protocol for SafetyBUS p
Supporting protocol for PROFINET IO
Voltage type for actuating
AC
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet Safety
Type of motor starter
Reversing starter
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Ambient temperature, upper operating limit
70°C
Rated conditional short-circuit current, type 2, 230 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Supporting protocol for PROFIsafe
Temperature compensated overload protection
Rated operation current at AC-3, 400 V
2.4A
Supporting protocol for Foundation Fieldbus