Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact0
Depth113.4mm
Rated operation power at AC-3, 400 V0.75kW
Height107.5mm
With transformerNo
Width22.6mm
Number of command positions0
Number of auxiliary contacts as normally open contact0
Overload release current setting0.18 - 2.4A
Number of indicator lights4
Rated operation current Ie2.4A
Suitable for emergency stopNo
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
Rail mounting possibleYes
Supporting protocol for TCP/IPNo
With fuseNo
Supporting protocol for LONNo
Supporting protocol for SUCONETNo
Release classCLASS 10
Rated control supply voltage Us at AC 60HZ110 - 230V
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Supporting protocol for other bus systemsNo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at DC- - -V
External reset possibleYes
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection of main circuitSpring clamp connection
Rated control supply voltage Us at AC 50HZ110 - 230V
Supporting protocol for Data-HighwayNo
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
With short-circuit releaseNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Voltage type for actuatingAC
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Type of motor starterReversing starter
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Ambient temperature, upper operating limit70°C
Rated conditional short-circuit current, type 2, 230 V-A
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated conditional short-circuit current, type 2, 400 V-A
Rated power, 460 V, 60 Hz, 3-phase0.75kW
Supporting protocol for PROFIsafeNo
Temperature compensated overload protectionYes
Rated operation current at AC-3, 400 V2.4A
Supporting protocol for Foundation FieldbusNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LZ2H2X43FU | Motorski Pok. Reverz. 0,18-2,4A 230VAC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Depth

113.4mm

Rated operation power at AC-3, 400 V

0.75kW

Height

107.5mm

With transformer

Width

22.6mm

Number of command positions

0

Number of auxiliary contacts as normally open contact

0

Overload release current setting

0.18 .. 2.4A

Number of indicator lights

4

Rated operation current Ie

2.4A

Suitable for emergency stop

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Rail mounting possible

Supporting protocol for TCP/IP

With fuse

Supporting protocol for LON

Supporting protocol for SUCONET

Release class

CLASS 10

Rated control supply voltage Us at AC 60HZ

110 .. 230V

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for INTERBUS-Safety

Rated control supply voltage Us at DC

- .. -V

External reset possible

Supporting protocol for AS-Interface Safety at Work

Type of electrical connection of main circuit

Spring clamp connection

Rated control supply voltage Us at AC 50HZ

110 .. 230V

Supporting protocol for Data-Highway

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

With short-circuit release

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Voltage type for actuating

AC

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Type of motor starter

Reversing starter

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Ambient temperature, upper operating limit

70°C

Rated conditional short-circuit current, type 2, 230 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated power, 460 V, 60 Hz, 3-phase

0.75kW

Supporting protocol for PROFIsafe

Temperature compensated overload protection

Rated operation current at AC-3, 400 V

2.4A

Supporting protocol for Foundation Fieldbus

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.