Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width22.6mm
Depth113.4mm
Height106.5mm
Rated operation power at AC-3, 400 V0.75kW
With transformerNo
Rated operation current Ie2.4A
Number of indicator lights4
Overload release current setting0.18 - 2.4A
Suitable for emergency stopNo
Number of command positions0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Supporting protocol for CANNo
Rail mounting possibleYes
Supporting protocol for INTERBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Rated control supply voltage Us at AC 50HZ110 - 230V
Supporting protocol for other bus systemsNo
Supporting protocol for ModbusNo
Supporting protocol for PROFIBUSNo
Supporting protocol for LONNo
Rated control supply voltage Us at DC- - -V
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 60HZ110 - 230V
Degree of protection (IP)IP20
External reset possibleYes
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection of main circuitScrew connection
With fuseNo
With short-circuit releaseNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SERCOSNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Release classCLASS 10
Supporting protocol for DeviceNet SafetyNo
Type of motor starterReversing starter
Supporting protocol for EtherNet/IPNo
Voltage type for actuatingAC
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Supporting protocol for SafetyBUS pNo
Rated power, 460 V, 60 Hz, 3-phase0.75kW
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated operation current at AC-3, 400 V2.4A
Ambient temperature, upper operating limit70°C
Rated conditional short-circuit current, type 2, 400 V-A
Rated conditional short-circuit current, type 2, 230 V-A
Temperature compensated overload protectionYes
Rated power, 575 V, 60 Hz, 3-phase-kW
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LZ2H2X4FU | Motorski Pok. Reverz. 0,18-2,4A 230VAC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

22.6mm

Depth

113.4mm

Height

106.5mm

Rated operation power at AC-3, 400 V

0.75kW

With transformer

Rated operation current Ie

2.4A

Number of indicator lights

4

Overload release current setting

0.18 .. 2.4A

Suitable for emergency stop

Number of command positions

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for CAN

Rail mounting possible

Supporting protocol for INTERBUS

Supporting protocol for TCP/IP

Supporting protocol for ASI

Rated control supply voltage Us at AC 50HZ

110 .. 230V

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Supporting protocol for LON

Rated control supply voltage Us at DC

- .. -V

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Rated control supply voltage Us at AC 60HZ

110 .. 230V

Degree of protection (IP)

IP20

External reset possible

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

Type of electrical connection of main circuit

Screw connection

With fuse

With short-circuit release

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SERCOS

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Release class

CLASS 10

Supporting protocol for DeviceNet Safety

Type of motor starter

Reversing starter

Supporting protocol for EtherNet/IP

Voltage type for actuating

AC

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Supporting protocol for SafetyBUS p

Rated power, 460 V, 60 Hz, 3-phase

0.75kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated operation current at AC-3, 400 V

2.4A

Ambient temperature, upper operating limit

70°C

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Temperature compensated overload protection

Rated power, 575 V, 60 Hz, 3-phase

-kW

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.