Details
- •Low-voltage industrial components
- •Motor starter/Motor starter combination
- •1 KOM
- •SCHNEIDER
Technical specifications
LZ2H6X53BD | Motorski Pok. Reverz. 1,5-6,5A 24VDC

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
With transformer
Depth
113.4mm
Width
22.6mm
Height
107.5mm
Number of auxiliary contacts as normally open contact
0
Rated operation power at AC-3, 400 V
3kW
Rated operation current Ie
9A
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
1.5 .. 6.5A
Supporting protocol for LON
Suitable for emergency stop
Number of command positions
0
Number of indicator lights
4
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Degree of protection (IP)
IP20
Rated control supply voltage Us at AC 60HZ
- .. -V
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Rated control supply voltage Us at AC 50HZ
- .. -V
External reset possible
Supporting protocol for other bus systems
Rail mounting possible
Rated control supply voltage Us at DC
24 .. 24V
Type of electrical connection of main circuit
Spring clamp connection
With short-circuit release
With fuse
Supporting protocol for SERCOS
Release class
CLASS 10
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Supporting protocol for EtherNet/IP
Supporting protocol for SafetyBUS p
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Voltage type for actuating
DC
Type of motor starter
Reversing starter
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 230 V
-A
Ambient temperature, upper operating limit
70°C
Temperature compensated overload protection
Rated conditional short-circuit current, type 2, 400 V
-A
Rated operation current at AC-3, 400 V
6.5A
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated power, 460 V, 60 Hz, 3-phase
3kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A