Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 60HZ- - -V
Rated control supply voltage Us at AC 50HZ- - -V
Rated conditional short-circuit current, type 2, 400 V-A
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 2, 230 V-A
With short-circuit releaseNo
Type of motor starterReversing starter
Rated control supply voltage Us at DC24 - 24V
Voltage type for actuatingDC
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Rated operation current at AC-3, 400 V6.5A
Rated operation power at AC-3, 400 V3kW
Rated power, 460 V, 60 Hz, 3-phase3kW
Overload release current setting1.5 - 6.5A
Number of auxiliary contacts as normally closed contact0
Rated operation current Ie9A
Number of auxiliary contacts as normally open contact0
Type of electrical connection for auxiliary- and control current circuitScrew connection
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit70°C
Rail mounting possibleYes
Type of electrical connection of main circuitScrew connection
With transformerNo
Suitable for emergency stopNo
Release classCLASS 10
With fuseNo
Supporting protocol for TCP/IPNo
Number of command positions0
External reset possibleYes
Number of indicator lights4
Supporting protocol for PROFIBUSNo
Degree of protection (IP)IP20
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Supporting protocol for LONNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFINET IONo
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for INTERBUS-SafetyNo
Width22.6mm
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Height106.5mm
Depth113.4mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LZ2H6X5BD

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated conditional short-circuit current, type 2, 400 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

With short-circuit release

Type of motor starter

Reversing starter

Rated control supply voltage Us at DC

24 .. 24V

Voltage type for actuating

DC

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rated operation current at AC-3, 400 V

6.5A

Rated operation power at AC-3, 400 V

3kW

Rated power, 460 V, 60 Hz, 3-phase

3kW

Overload release current setting

1.5 .. 6.5A

Number of auxiliary contacts as normally closed contact

0

Rated operation current Ie

9A

Number of auxiliary contacts as normally open contact

0

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Temperature compensated overload protection

Ambient temperature, upper operating limit

70°C

Rail mounting possible

Type of electrical connection of main circuit

Screw connection

With transformer

Suitable for emergency stop

Release class

CLASS 10

With fuse

Supporting protocol for TCP/IP

Number of command positions

0

External reset possible

Number of indicator lights

4

Supporting protocol for PROFIBUS

Degree of protection (IP)

IP20

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for LON

Supporting protocol for Data-Highway

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for INTERBUS-Safety

Width

22.6mm

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Height

106.5mm

Depth

113.4mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.