Details
- •Low-voltage industrial components
- •Motor starter/Motor starter combination
- •1 KOM
- •SCHNEIDER
Technical specifications
LZ7H6X53BD | Motorski Pok. Dir. 1,5-6,5A 24VDC FS

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Width
22.6mm
Height
107.5mm
Supporting protocol for CAN
Rated operation power at AC-3, 400 V
3kW
Supporting protocol for ASI
Number of indicator lights
3
Supporting protocol for LON
Rated operation current Ie
9A
Supporting protocol for Modbus
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1.5 .. 6.5A
Depth
113.4mm
Supporting protocol for INTERBUS
Number of command positions
0
Supporting protocol for TCP/IP
Number of auxiliary contacts as normally closed contact
0
With transformer
Suitable for emergency stop
Supporting protocol for PROFIBUS
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Type of electrical connection of main circuit
Spring clamp connection
Supporting protocol for other bus systems
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for AS-Interface Safety at Work
Release class
CLASS 10
Supporting protocol for PROFINET CBA
Supporting protocol for INTERBUS-Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for DeviceNet Safety
Rail mounting possible
With fuse
With short-circuit release
Degree of protection (IP)
IP20
Supporting protocol for SERCOS
Rated control supply voltage Us at AC 50HZ
- .. -V
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Rated control supply voltage Us at AC 60HZ
- .. -V
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
DC
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
External reset possible
Rated power, 460 V, 60 Hz, 3-phase
3kW
Rated operation current at AC-3, 400 V
6.5A
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated conditional short-circuit current, type 2, 400 V
-A
Ambient temperature, upper operating limit
70°C
Temperature compensated overload protection
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW