Aleta.hr
Main Product Image

LZ8H2X43BD

Code: 1758383

ManufacturerSchneider
Catalog numberLZ8H2X43BD
Type
EAN code3606485421100

















Details

  • Low-voltage switchgear and control gear (automation)
  • Motor starter/motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ- - -V
Rated control supply voltage Us at AC 60HZ- - -V
Rated conditional short-circuit current, type 2, 400 V-A
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 2, 230 V-A
Type of motor starterReversing starter
Rated power, 460 V, 60 Hz, 3-phase0.75kW
Rated control supply voltage Us at DC24 - 24V
With short-circuit releaseNo
Voltage type for actuatingDC
Release classCLASS 10
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Temperature compensated overload protectionYes
Number of auxiliary contacts as normally open contact0
Rated operation power at AC-3, 400 V0.75kW
Number of auxiliary contacts as normally closed contact0
Rated operation current Ie2.4A
Ambient temperature, upper operating limit70°C
Overload release current setting0.18 - 2.4A
Rated operation current at AC-3, 400 V2.4A
Type of electrical connection of main circuitSpring clamp connection
With transformerNo
Number of command positions0
Rail mounting possibleYes
Number of indicator lights4
External reset possibleYes
Suitable for emergency stopYes
With fuseNo
Degree of protection (IP)IP20
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFINET IONo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for ASINo
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Depth113.4mm
Height107.5mm
Width22.6mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LZ8H2X43BD

Main Product Image

Details

  • Low-voltage switchgear and control gear (automation)
  • Motor starter/motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Type of motor starter

Reversing starter

Rated power, 460 V, 60 Hz, 3-phase

0.75kW

Rated control supply voltage Us at DC

24 .. 24V

With short-circuit release

Voltage type for actuating

DC

Release class

CLASS 10

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Temperature compensated overload protection

Number of auxiliary contacts as normally open contact

0

Rated operation power at AC-3, 400 V

0.75kW

Number of auxiliary contacts as normally closed contact

0

Rated operation current Ie

2.4A

Ambient temperature, upper operating limit

70°C

Overload release current setting

0.18 .. 2.4A

Rated operation current at AC-3, 400 V

2.4A

Type of electrical connection of main circuit

Spring clamp connection

With transformer

Number of command positions

0

Rail mounting possible

Number of indicator lights

4

External reset possible

Suitable for emergency stop

With fuse

Degree of protection (IP)

IP20

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for ASI

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Depth

113.4mm

Height

107.5mm

Width

22.6mm