Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width22.6mm
Height107.5mm
Depth113.4mm
With transformerNo
Supporting protocol for LONNo
Supporting protocol for other bus systemsNo
Rated operation power at AC-3, 400 V0.75kW
Overload release current setting0.18 - 2.4A
Number of auxiliary contacts as normally closed contact0
Supporting protocol for ASINo
Number of indicator lights4
Supporting protocol for INTERBUSNo
Number of auxiliary contacts as normally open contact0
Number of command positions0
Suitable for emergency stopYes
External reset possibleYes
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Rail mounting possibleYes
Supporting protocol for DeviceNetNo
Rated control supply voltage Us at AC 50HZ110 - 230V
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Rated operation current Ie2.4A
Supporting protocol for TCP/IPNo
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ110 - 230V
Rated control supply voltage Us at DC- - -V
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection of main circuitSpring clamp connection
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
With short-circuit releaseNo
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Release classCLASS 10
Supporting protocol for PROFINET CBANo
Type of motor starterReversing starter
Rated power, 460 V, 60 Hz, 3-phase0.75kW
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Supporting protocol for PROFIsafeNo
Voltage type for actuatingAC
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
With fuseNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Rated conditional short-circuit current, type 2, 230 V-A
Ambient temperature, upper operating limit70°C
Rated conditional short-circuit current, type 2, 400 V-A
Temperature compensated overload protectionYes
Rated operation current at AC-3, 400 V2.4A
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

LZ8H2X43FU

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

22.6mm

Height

107.5mm

Depth

113.4mm

With transformer

Supporting protocol for LON

Supporting protocol for other bus systems

Rated operation power at AC-3, 400 V

0.75kW

Overload release current setting

0.18 .. 2.4A

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for ASI

Number of indicator lights

4

Supporting protocol for INTERBUS

Number of auxiliary contacts as normally open contact

0

Number of command positions

0

Suitable for emergency stop

External reset possible

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Rail mounting possible

Supporting protocol for DeviceNet

Rated control supply voltage Us at AC 50HZ

110 .. 230V

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Rated operation current Ie

2.4A

Supporting protocol for TCP/IP

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

110 .. 230V

Rated control supply voltage Us at DC

- .. -V

Supporting protocol for DeviceNet Safety

Type of electrical connection of main circuit

Spring clamp connection

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

With short-circuit release

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Release class

CLASS 10

Supporting protocol for PROFINET CBA

Type of motor starter

Reversing starter

Rated power, 460 V, 60 Hz, 3-phase

0.75kW

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Supporting protocol for PROFIsafe

Voltage type for actuating

AC

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

With fuse

Supporting protocol for INTERBUS-Safety

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Rated conditional short-circuit current, type 2, 230 V

-A

Ambient temperature, upper operating limit

70°C

Rated conditional short-circuit current, type 2, 400 V

-A

Temperature compensated overload protection

Rated operation current at AC-3, 400 V

2.4A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.