Technical specifications
Height
106.5mm
Width
22.6mm
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for TCP/IP
Supporting protocol for LON
Overload release current setting
0.18 .. 2.4A
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for SUCONET
Number of command positions
0
Number of auxiliary contacts as normally open contact
0
Depth
113.4mm
With transformer
Rated operation current Ie
2.4A
Supporting protocol for PROFIBUS
Rail mounting possible
Number of indicator lights
4
Supporting protocol for other bus systems
Supporting protocol for INTERBUS
Suitable for emergency stop
External reset possible
Supporting protocol for DeviceNet
Rated operation power at AC-3, 400 V
0.75kW
Supporting protocol for Modbus
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Supporting protocol for Data-Highway
Degree of protection (IP)
IP20
With short-circuit release
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Release class
CLASS 10
Supporting protocol for INTERBUS-Safety
Supporting protocol for EtherNet/IP
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFINET CBA
With fuse
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Voltage type for actuating
DC
Type of motor starter
Reversing starter
Ambient temperature, upper operating limit
70°C
Temperature compensated overload protection
Rated operation current at AC-3, 400 V
2.4A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for SERCOS
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET IO
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated conditional short-circuit current, type 2, 230 V
-A
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A