Technical specifications
TM241C40T | PLC Compact 40IO Transistor PNP

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Depth
95mm
Number of digital inputs
24
Number of digital outputs
16
Width
190mm
Model
Compact
With display
Height
90mm
Number of HW-interfaces industrial Ethernet
0
Voltage type of supply voltage
DC
Number of analogue inputs
0
Number of analogue outputs
0
Processing time (1K, binary operation)
0.022ms
Number of HW-interfaces RS-422
0
Type of memory
NVRAM
Number of HW-interfaces RS-232
2
Supporting protocol for LON
Memory size
64000kByte
Number of HW-interfaces RS-485
2
Number of HW-interfaces USB
1
Suitable for safety functions
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Additional program memory possible
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for CAN
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Supporting protocol for PROFIBUS
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for TCP/IP
With optical interface
Redundancy
Rail mounting possible
Explosion safety category for dust
None
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Supporting protocol for SERCOS
System accessory
Explosion safety category for gas
None
Number of interfaces PROFINET
0
Front built-in possible
Number of HW-interfaces Wireless
0
Performance level according to EN ISO 13849-1
None
Radio standard Wi-Fi 802.11
Rack-assembly possible
IO link master
Number of relay outputs
0
Supporting protocol for EtherNet/IP
Max. number of time switches
0
Supporting protocol for AS-Interface Safety at Work
Wall mounting/direct mounting
Radio standard Bluetooth
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Radio standard UMTS
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage DC
19.2 .. 28.8V
Supporting protocol for SafetyBUS p
Radio standard GPRS
Supporting protocol for PROFIsafe
Radio standard GSM
Supporting protocol for PROFINET IO
Supply voltage AC 50 Hz
0 .. 0V
Supporting protocol for Foundation Fieldbus
Supporting protocol for IEC 61850 Ethernet
SIL according to IEC 61508
None
Supporting protocol for DNP3
Supporting protocol for EtherCAT
Radio standard 4G
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location division 2
Supporting protocol for IEC 60870
Certified for UL hazardous location class III
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location class II
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location class I
Certified for UL hazardous location division 1
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group D (propane)