Details
- Sensors
- Light curtain
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Response time
-ms
Scope of delivery of the one-way system
Transmitter and receiver
Type of interface for safety communication
Other
Number of semiconductor outputs with signalling function
0
Number of contact energized outputs with signalling function
0
Number of protected semiconductor outputs
2
Fade-out possible
No
Number of protected contact energized outputs
0
Type of electric connection
Connector M12
Height of sensor
837mm
Explosion safety category for gas
None
Operation agent-safety class
Safety class 3
Explosion safety category for dust
None
Width sensor
29.4mm
Cascadable
Yes
Max. output current at protected output
400mA
Override possible
No
Resolution of the light curtain
14mm
Transmission range of the safety field
6m
Reduced resolution
No
Ambient temperature
-10 - 55°C
Length of sensor
31mm
Type of switching output of the OSSD
PNP/PNP
Detection capability for test bodies
14mm
Rated control supply voltage Us at DC
24 - 24V
Safety field height
760mm
Clock control possible
No
With muting function
Yes
Type of safety according to IEC 61496-1
4
Switching voltage of OSSD at state "high"
24V
Suitable for safety functions
Yes
With restart blockage
Yes
Wavelength of the sensor
950nm
With beam coding
No
Degree of protection (IP)
IP65
Voltage type
AC/DC
With monitoring function downstream switching devices
No
From same serie
XUSL4E14F076NM

Details
- Sensors
- Light curtain
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Response time
-ms
Scope of delivery of the one-way system
Transmitter and receiver
Type of interface for safety communication
Other
Number of semiconductor outputs with signalling function
0
Number of contact energized outputs with signalling function
0
Number of protected semiconductor outputs
2
Fade-out possible
Number of protected contact energized outputs
0
Type of electric connection
Connector M12
Height of sensor
837mm
Explosion safety category for gas
None
Operation agent-safety class
Safety class 3
Explosion safety category for dust
None
Width sensor
29.4mm
Cascadable
Max. output current at protected output
400mA
Override possible
Resolution of the light curtain
14mm
Transmission range of the safety field
6m
Reduced resolution
Ambient temperature
-10 .. 55°C
Length of sensor
31mm
Type of switching output of the OSSD
PNP/PNP
Detection capability for test bodies
14mm
Rated control supply voltage Us at DC
24 .. 24V
Safety field height
760mm
Clock control possible
With muting function
Type of safety according to IEC 61496-1
4
Switching voltage of OSSD at state "high"
24V
Suitable for safety functions
With restart blockage
Wavelength of the sensor
950nm
With beam coding
Degree of protection (IP)
IP65
Voltage type
AC/DC
With monitoring function downstream switching devices
From same serie