Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- HAGER
Technical specifications
Version as maintenance-/service switch
Yes
Version as main switch
Yes
Version as reversing switch
No
Number of switches
1
Rated permanent current at AC-21, 400 V
32A
Rated permanent current Iu
32A
Rated permanent current at AC-23, 400 V
32A
Version as emergency stop installation
No
Rated operating voltage
380 - 415V
Version as safety switch
Yes
Max. rated operation voltage Ue AC
415V
Rated short-time withstand current lcw
1.26kA
Rated operation power at AC-23, 400 V
14kW
Switching power at 400 V
21kW
Number of auxiliary contacts as normally open contact
0
Number of poles
4
Suitable for distribution board installation
Yes
Number of auxiliary contacts as change-over contact
0
Voltage release optional
No
Suitable for front mounting centre
No
Degree of protection (IP), front side
IP20
Suitable for front mounting 4-hole
No
Width in number of modular spacings
3.5
Depth
69mm
Conditioned rated short-circuit current Iq
50kA
Number of auxiliary contacts as normally closed contact
0
Height
68mm
Motor drive optional
No
Suitable for floor mounting
Yes
Type of electrical connection of main circuit
Screw connection
Type of control element
Short thumb-grip
Width
60mm
Colour control element
Grey
With pre-assembled cabling
No
Suitable for intermediate mounting
No
Interlockable
Yes
Motor drive integrated
No
Degree of protection (NEMA)
Other
Device construction
Built-in device fixed built-in technique
HAB403

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- HAGER
Technical specifications
Version as maintenance-/service switch
Version as main switch
Version as reversing switch
Number of switches
1
Rated permanent current at AC-21, 400 V
32A
Rated permanent current Iu
32A
Rated permanent current at AC-23, 400 V
32A
Version as emergency stop installation
Rated operating voltage
380 .. 415V
Version as safety switch
Max. rated operation voltage Ue AC
415V
Rated short-time withstand current lcw
1.26kA
Rated operation power at AC-23, 400 V
14kW
Switching power at 400 V
21kW
Number of auxiliary contacts as normally open contact
0
Number of poles
4
Suitable for distribution board installation
Number of auxiliary contacts as change-over contact
0
Voltage release optional
Suitable for front mounting centre
Degree of protection (IP), front side
IP20
Suitable for front mounting 4-hole
Width in number of modular spacings
3.5
Depth
69mm
Conditioned rated short-circuit current Iq
50kA
Number of auxiliary contacts as normally closed contact
0
Height
68mm
Motor drive optional
Suitable for floor mounting
Type of electrical connection of main circuit
Screw connection
Type of control element
Short thumb-grip
Width
60mm
Colour control element
Grey
With pre-assembled cabling
Suitable for intermediate mounting
Interlockable
Motor drive integrated
Degree of protection (NEMA)
Other
Device construction
Built-in device fixed built-in technique