Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Degree of protection (IP)IP40
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu630A
Number of auxiliary contacts as normally closed contact0
Overload release current setting250 - 630A
Rated voltage220 - 690V
Motor drive optionalYes
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release3500 - 6300A
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Integrated earth fault protectionNo
With under voltage releaseNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HED630H

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Degree of protection (IP)

IP40

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

630A

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

250 .. 630A

Rated voltage

220 .. 690V

Motor drive optional

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

3500 .. 6300A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Integrated earth fault protection

With under voltage release

Related products