Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Rated permanent current Iu1600A
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release8960 - 19200A
Power loss168.90W
With switched-off indicatorNo
With integrated under voltage releaseNo
Overload release current setting640 - 1600A
Adjustment range short-term delayed short-circuit release0 - 0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Rated voltage220 - 690V
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device fixed built-in technique
Number of poles3
Type of control elementToggle
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Integrated earth fault protectionNo
Motor drive integratedNo
Degree of protection (IP)IP40

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HEF990H

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Rated permanent current Iu

1600A

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

8960 .. 19200A

Power loss

168.90W

With switched-off indicator

With integrated under voltage release

Overload release current setting

640 .. 1600A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device fixed built-in technique

Number of poles

3

Type of control element

Toggle

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Integrated earth fault protection

Motor drive integrated

Degree of protection (IP)

IP40

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.