Adjustment range short-term delayed short-circuit releaseA
Overload release current setting50 - 80A
Rated permanent current Iu80A
Type of electrical connection of main circuitScrew connection
Power loss32.1W
Adjustment range undelayed short-circuit release1000 - 1000A
Rated voltage220 - 415V
Suitable for DIN rail (top hat rail) mountingYes
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
With switched-off indicatorYes
Position of connection for main current circuitFront side
Number of poles3
Device constructionBuilt-in device fixed built-in technique
With integrated under voltage releaseNo
Motor drive integratedNo
Type of control elementToggle
Motor drive optionalNo
Complete device with protection unitYes
Degree of protection (IP)IP40
Integrated earth fault protectionNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HHA080H

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Adjustment range short-term delayed short-circuit release

A

Overload release current setting

50 .. 80A

Rated permanent current Iu

80A

Type of electrical connection of main circuit

Screw connection

Power loss

32.1W

Adjustment range undelayed short-circuit release

1000 .. 1000A

Rated voltage

220 .. 415V

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Position of connection for main current circuit

Front side

Number of poles

3

Device construction

Built-in device fixed built-in technique

With integrated under voltage release

Motor drive integrated

Type of control element

Toggle

Motor drive optional

Complete device with protection unit

Degree of protection (IP)

IP40

Integrated earth fault protection

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.