Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Adjustment range short-term delayed short-circuit releaseA
Rated permanent current Iu125A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Adjustment range undelayed short-circuit release1500 - 1500A
Rated voltage220 - 415V
Overload release current setting80 - 125A
Power loss33W
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingYes
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Number of poles4
Position of connection for main current circuitFront side
Type of control elementToggle
Motor drive optionalNo
Motor drive integratedNo
Degree of protection (IP)IP40
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HHA126H

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Adjustment range short-term delayed short-circuit release

A

Rated permanent current Iu

125A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Adjustment range undelayed short-circuit release

1500 .. 1500A

Rated voltage

220 .. 415V

Overload release current setting

80 .. 125A

Power loss

33W

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Number of poles

4

Position of connection for main current circuit

Front side

Type of control element

Toggle

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP40

Complete device with protection unit