Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • HAGER

Technical specifications

Number of poles4
Type of control elementLong turning handle
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu800A
Type of electrical connection of main circuitCable clamp
Motor drive optionalNo
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Rated operation power at AC-3, 400 V-kW
Suitable for floor mountingYes
Suitable for intermediate mountingNo
Suitable for distribution board installationYes
Degree of protection (IP), front sideIP00
Max. rated operation voltage Ue AC690V
Conditioned rated short-circuit current Iq50kA
Rated operating voltage380 - 690V
Rated operation power at AC-23, 400 V360kW
Suitable for front mounting 4-holeNo
Voltage release optionalNo
Version as maintenance-/service switchYes
InterlockableYes
Switching power at 400 V526kW
Rated short-time withstand current lcw64kA
Version as safety switchYes
Suitable for front mounting centreNo
Version as emergency stop installationNo
Rated permanent current at AC-21, 400 V-A
Version as reversing switchYes
Version as main switchYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HI460

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • HAGER

Technical specifications

Number of poles

4

Type of control element

Long turning handle

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

800A

Type of electrical connection of main circuit

Cable clamp

Motor drive optional

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Rated operation power at AC-3, 400 V

-kW

Suitable for floor mounting

Suitable for intermediate mounting

Suitable for distribution board installation

Degree of protection (IP), front side

IP00

Max. rated operation voltage Ue AC

690V

Conditioned rated short-circuit current Iq

50kA

Rated operating voltage

380 .. 690V

Rated operation power at AC-23, 400 V

360kW

Suitable for front mounting 4-hole

Voltage release optional

Version as maintenance-/service switch

Interlockable

Switching power at 400 V

526kW

Rated short-time withstand current lcw

64kA

Version as safety switch

Suitable for front mounting centre

Version as emergency stop installation

Rated permanent current at AC-21, 400 V

-A

Version as reversing switch

Version as main switch

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.