Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • HAGER

Technical specifications

Number of poles4
Type of control elementOther
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact1
Rated permanent current Iu160A
Type of electrical connection of main circuitCable clamp
Motor drive optionalNo
Device constructionComplete device in housing
Motor drive integratedYes
Number of auxiliary contacts as change-over contact0
Rated operation power at AC-3, 400 V-kW
Suitable for floor mountingYes
Suitable for intermediate mountingNo
Suitable for distribution board installationYes
Degree of protection (IP), front sideIP00
Max. rated operation voltage Ue AC415V
Conditioned rated short-circuit current Iq100kA
Rated operating voltage380 - 415V
Rated operation power at AC-23, 400 V72kW
Colour control elementOther
Suitable for front mounting 4-holeNo
Voltage release optionalNo
Version as maintenance-/service switchYes
InterlockableYes
Switching power at 400 V105kW
Rated short-time withstand current lcw7kA
Version as safety switchYes
Suitable for front mounting centreNo
Version as emergency stop installationNo
Rated permanent current at AC-21, 400 V160A
Version as reversing switchYes
Version as main switchYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HIB416M

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • HAGER

Technical specifications

Number of poles

4

Type of control element

Other

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Rated permanent current Iu

160A

Type of electrical connection of main circuit

Cable clamp

Motor drive optional

Device construction

Complete device in housing

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Rated operation power at AC-3, 400 V

-kW

Suitable for floor mounting

Suitable for intermediate mounting

Suitable for distribution board installation

Degree of protection (IP), front side

IP00

Max. rated operation voltage Ue AC

415V

Conditioned rated short-circuit current Iq

100kA

Rated operating voltage

380 .. 415V

Rated operation power at AC-23, 400 V

72kW

Colour control element

Other

Suitable for front mounting 4-hole

Voltage release optional

Version as maintenance-/service switch

Interlockable

Switching power at 400 V

105kW

Rated short-time withstand current lcw

7kA

Version as safety switch

Suitable for front mounting centre

Version as emergency stop installation

Rated permanent current at AC-21, 400 V

160A

Version as reversing switch

Version as main switch

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.