Aleta.hr
Main Product Image

HMC180

Code: 1761893

ManufacturerHager
Catalog numberHMC180
EAN code3250613230135

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class-
Built-in depth70mm
Rated voltage415V
Number of protected poles1
Power loss6.18W
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Frequency50 - 60Hz
Voltage typeAC
Number of poles (total)1
Release characteristicC
Rated current80A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Pollution degree3
Over voltage category3
Flush-mounted installationYes
Rated insulation voltage Ui500V
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section solid-core1 - 70mm²
Width in number of modular spacings1.5
Explosion-proofNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 50mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMC180

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class

-

Built-in depth

70mm

Rated voltage

415V

Number of protected poles

1

Power loss

6.18W

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Frequency

50 .. 60Hz

Voltage type

AC

Number of poles (total)

1

Release characteristic

C

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Pollution degree

3

Over voltage category

3

Flush-mounted installation

Rated insulation voltage Ui

500V

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section solid-core

1 .. 70mm²

Width in number of modular spacings

1.5

Explosion-proof

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 50mm²

Related products