Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Built-in depth70mm
Frequency50 - 60Hz
Voltage typeAC
Rated insulation voltage Ui500V
Release characteristicC
Rated current80A
Rated voltage415V
Power loss6.18W
Concurrently switching neutral conductorNo
Number of protected poles1
Current limiting class-
Degree of protection (IP)IP20
Pollution degree3
Over voltage category3
Width in number of modular spacings1.5
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Flush-mounted installationYes
Connectable conductor cross section solid-core1 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Connectable conductor cross section multi-wired1 - 50mm²
Rated impulse withstand voltage Uimp6kV
Ambient temperature during operating-25 - 70°C
Number of poles (total)1

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMC180

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Built-in depth

70mm

Frequency

50 .. 60Hz

Voltage type

AC

Rated insulation voltage Ui

500V

Release characteristic

C

Rated current

80A

Rated voltage

415V

Power loss

6.18W

Concurrently switching neutral conductor

Number of protected poles

1

Current limiting class

-

Degree of protection (IP)

IP20

Pollution degree

3

Over voltage category

3

Width in number of modular spacings

1.5

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Flush-mounted installation

Connectable conductor cross section solid-core

1 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Connectable conductor cross section multi-wired

1 .. 50mm²

Rated impulse withstand voltage Uimp

6kV

Ambient temperature during operating

-25 .. 70°C

Number of poles (total)

1

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.