Aleta.hr
Main Product Image

HMC199

Code: 1761895

ManufacturerHager
Catalog numberHMC199
EAN code3250613230159

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class-
Rated insulation voltage Ui500V
Built-in depth70mm
Rated current125A
Number of poles (total)1
Number of protected poles1
Release characteristicC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Power loss9.93W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Frequency50 - 60Hz
Voltage typeAC
Rated impulse withstand voltage Uimp6kV
Flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated voltage415V
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 50mm²
Over voltage category3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section solid-core1 - 70mm²
Explosion-proofNo
Width in number of modular spacings1.5
Pollution degree3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMC199

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class

-

Rated insulation voltage Ui

500V

Built-in depth

70mm

Rated current

125A

Number of poles (total)

1

Number of protected poles

1

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Power loss

9.93W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Frequency

50 .. 60Hz

Voltage type

AC

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated voltage

415V

Concurrently switching neutral conductor

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 50mm²

Over voltage category

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section solid-core

1 .. 70mm²

Explosion-proof

Width in number of modular spacings

1.5

Pollution degree

3

Related products