Aleta.hr
Main Product Image

HMC280

Code: 1761896

ManufacturerHager
Catalog numberHMC280
EAN code3250613230166

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class-
Number of protected poles2
Release characteristicC
Number of poles (total)2
Rated voltage415V
Built-in depth70mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated current80A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Voltage typeAC
Power loss11.98W
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Pollution degree3
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Over voltage category3
Flush-mounted installationYes
Ambient temperature during operating-25 - 70°C
Degree of protection (IP)IP20
Width in number of modular spacings3
Connectable conductor cross section multi-wired1 - 50mm²
Explosion-proofNo
Connectable conductor cross section solid-core1 - 70mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMC280

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class

-

Number of protected poles

2

Release characteristic

C

Number of poles (total)

2

Rated voltage

415V

Built-in depth

70mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Voltage type

AC

Power loss

11.98W

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Pollution degree

3

Additional equipment possible

Concurrently switching neutral conductor

Over voltage category

3

Flush-mounted installation

Ambient temperature during operating

-25 .. 70°C

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

1 .. 50mm²

Explosion-proof

Connectable conductor cross section solid-core

1 .. 70mm²

Related products