Technical specifications

Current limiting class-
Number of poles (total)2
Release characteristicC
Rated impulse withstand voltage Uimp6kV
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated current125A
Rated insulation voltage Ui500V
Voltage typeAC
Built-in depth70mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated voltage415V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Power loss21W
Concurrently switching neutral conductorNo
Flush-mounted installationYes
Over voltage category3
Additional equipment possibleYes
Pollution degree3
Frequency50 - 60Hz
Ambient temperature during operating-25 - 70°C
Width in number of modular spacings3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 50mm²
Connectable conductor cross section solid-core1 - 70mm²
Explosion-proofNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMC299

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class

-

Number of poles (total)

2

Release characteristic

C

Rated impulse withstand voltage Uimp

6kV

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated current

125A

Rated insulation voltage Ui

500V

Voltage type

AC

Built-in depth

70mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated voltage

415V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Power loss

21W

Concurrently switching neutral conductor

Flush-mounted installation

Over voltage category

3

Additional equipment possible

Pollution degree

3

Frequency

50 .. 60Hz

Ambient temperature during operating

-25 .. 70°C

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 50mm²

Connectable conductor cross section solid-core

1 .. 70mm²

Explosion-proof