Aleta.hr
Main Product Image

HMC390

Code: 1761900

ManufacturerHager
Catalog numberHMC390
EAN code3250613230203

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Built-in depth70mm
Release characteristicC
Number of poles (total)3
Number of protected poles3
Rated impulse withstand voltage Uimp6kV
Rated voltage415V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Voltage typeAC
Power loss21.66W
Current limiting class3
Flush-mounted installationYes
Rated current100A
Pollution degree3
Concurrently switching neutral conductorNo
Over voltage category3
Rated insulation voltage Ui500V
Additional equipment possibleYes
Width in number of modular spacings4.5
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section solid-core1 - 70mm²
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 50mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMC390

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Built-in depth

70mm

Release characteristic

C

Number of poles (total)

3

Number of protected poles

3

Rated impulse withstand voltage Uimp

6kV

Rated voltage

415V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Voltage type

AC

Power loss

21.66W

Current limiting class

3

Flush-mounted installation

Rated current

100A

Pollution degree

3

Concurrently switching neutral conductor

Over voltage category

3

Rated insulation voltage Ui

500V

Additional equipment possible

Width in number of modular spacings

4.5

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section solid-core

1 .. 70mm²

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 50mm²