Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class-
Built-in depth70mm
Rated voltage415V
Rated current125A
Number of protected poles3
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Number of poles (total)3
Power loss34.93W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Concurrently switching neutral conductorNo
Flush-mounted installationYes
Release characteristicC
Over voltage category3
Width in number of modular spacings4.5
Pollution degree3
Degree of protection (IP)IP20
Frequency50 - 60Hz
Ambient temperature during operating-25 - 70°C
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 50mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 70mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMC399

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class

-

Built-in depth

70mm

Rated voltage

415V

Rated current

125A

Number of protected poles

3

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Number of poles (total)

3

Power loss

34.93W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Concurrently switching neutral conductor

Flush-mounted installation

Release characteristic

C

Over voltage category

3

Width in number of modular spacings

4.5

Pollution degree

3

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Ambient temperature during operating

-25 .. 70°C

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 50mm²

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 70mm²