Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Voltage typeAC
Built-in depth70mm
Release characteristicC
Rated current80A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Frequency50 - 60Hz
Additional equipment possibleYes
Degree of protection (IP)IP20
Rated voltage415V
Number of protected poles4
Over voltage category3
Power loss25.71W
Width in number of modular spacings6
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp6kV
Concurrently switching neutral conductorNo
Flush-mounted installationYes
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section multi-wired1 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Connectable conductor cross section solid-core1 - 70mm²
Rated insulation voltage Ui500V
Pollution degree3
Current limiting class3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMC480

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Voltage type

AC

Built-in depth

70mm

Release characteristic

C

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Frequency

50 .. 60Hz

Additional equipment possible

Degree of protection (IP)

IP20

Rated voltage

415V

Number of protected poles

4

Over voltage category

3

Power loss

25.71W

Width in number of modular spacings

6

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

6kV

Concurrently switching neutral conductor

Flush-mounted installation

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section multi-wired

1 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Connectable conductor cross section solid-core

1 .. 70mm²

Rated insulation voltage Ui

500V

Pollution degree

3

Current limiting class

3

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.