Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Rated current100A
Voltage typeAC
Release characteristicC
Rated voltage415V
Current limiting class3
Rated insulation voltage Ui500V
Over voltage category3
Power loss28.10W
Number of protected poles4
Pollution degree3
Built-in depth70mm
Explosion-proofNo
Frequency50 - 60Hz
Degree of protection (IP)IP20
Width in number of modular spacings6
Connectable conductor cross section solid-core1 - 70mm²
Ambient temperature during operating-25 - 70°C
Concurrently switching neutral conductorNo
Flush-mounted installationYes
Connectable conductor cross section multi-wired1 - 50mm²
Additional equipment possibleYes
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMC490

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Rated current

100A

Voltage type

AC

Release characteristic

C

Rated voltage

415V

Current limiting class

3

Rated insulation voltage Ui

500V

Over voltage category

3

Power loss

28.10W

Number of protected poles

4

Pollution degree

3

Built-in depth

70mm

Explosion-proof

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Width in number of modular spacings

6

Connectable conductor cross section solid-core

1 .. 70mm²

Ambient temperature during operating

-25 .. 70°C

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 50mm²

Additional equipment possible

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.