Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Voltage typeAC
Rated current80A
Built-in depth70mm
Rated voltage415V
Number of poles (total)1
Release characteristicD
Number of protected poles1
Connectable conductor cross section solid-core1 - 70mm²
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Degree of protection (IP)IP20
Width in number of modular spacings1.5
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Ambient temperature during operating-25 - 70°C
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 50mm²
Power loss6.18W
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp6kV
Pollution degree3
Over voltage category3
Flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Frequency50 - 60Hz

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMD180

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Voltage type

AC

Rated current

80A

Built-in depth

70mm

Rated voltage

415V

Number of poles (total)

1

Release characteristic

D

Number of protected poles

1

Connectable conductor cross section solid-core

1 .. 70mm²

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Degree of protection (IP)

IP20

Width in number of modular spacings

1.5

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Ambient temperature during operating

-25 .. 70°C

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 50mm²

Power loss

6.18W

Additional equipment possible

Concurrently switching neutral conductor

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

6kV

Pollution degree

3

Over voltage category

3

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Frequency

50 .. 60Hz