Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Release characteristicD
Rated voltage415V
Frequency50 - 60Hz
Rated current100A
Rated insulation voltage Ui500V
Voltage typeAC
Built-in depth70mm
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 50mm²
Pollution degree3
Number of protected poles2
Connectable conductor cross section solid-core1 - 70mm²
Current limiting class-
Over voltage category3
Power loss16.33W
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Width in number of modular spacings3
Ambient temperature during operating-25 - 70°C
Explosion-proofNo
Flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp6kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMD290

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Release characteristic

D

Rated voltage

415V

Frequency

50 .. 60Hz

Rated current

100A

Rated insulation voltage Ui

500V

Voltage type

AC

Built-in depth

70mm

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 50mm²

Pollution degree

3

Number of protected poles

2

Connectable conductor cross section solid-core

1 .. 70mm²

Current limiting class

-

Over voltage category

3

Power loss

16.33W

Concurrently switching neutral conductor

Additional equipment possible

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 70°C

Explosion-proof

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

6kV

Related products