Aleta.hr
Main Product Image

HMD480

Code: 1761914

ManufacturerHager
Catalog numberHMD480
EAN code3250613230340

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Release characteristicD
Built-in depth70mm
Number of protected poles4
Number of poles (total)4
Rated voltage415V
Rated current80A
Rated impulse withstand voltage Uimp6kV
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Voltage typeAC
Frequency50 - 60Hz
Current limiting class3
Concurrently switching neutral conductorNo
Power loss25.71W
Flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Width in number of modular spacings6
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Connectable conductor cross section multi-wired1 - 50mm²
Over voltage category3
Connectable conductor cross section solid-core1 - 70mm²
Degree of protection (IP)IP20
Pollution degree3
Explosion-proofNo
Ambient temperature during operating-25 - 70°C

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMD480

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Release characteristic

D

Built-in depth

70mm

Number of protected poles

4

Number of poles (total)

4

Rated voltage

415V

Rated current

80A

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Voltage type

AC

Frequency

50 .. 60Hz

Current limiting class

3

Concurrently switching neutral conductor

Power loss

25.71W

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Width in number of modular spacings

6

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Connectable conductor cross section multi-wired

1 .. 50mm²

Over voltage category

3

Connectable conductor cross section solid-core

1 .. 70mm²

Degree of protection (IP)

IP20

Pollution degree

3

Explosion-proof

Ambient temperature during operating

-25 .. 70°C