Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Pollution degree3
Release characteristicC
Width in number of modular spacings1.5
Voltage typeAC
Explosion-proofNo
Rated current100A
Frequency50 - 60Hz
Over voltage category3
Power loss6.48W
Current limiting class-
Rated voltage415V
Rated insulation voltage Ui500V
Built-in depth70mm
Ambient temperature during operating-25 - 70°C
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Number of poles (total)1
Connectable conductor cross section solid-core1 - 70mm²
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wired1 - 50mm²
Flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMF190

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Pollution degree

3

Release characteristic

C

Width in number of modular spacings

1.5

Voltage type

AC

Explosion-proof

Rated current

100A

Frequency

50 .. 60Hz

Over voltage category

3

Power loss

6.48W

Current limiting class

-

Rated voltage

415V

Rated insulation voltage Ui

500V

Built-in depth

70mm

Ambient temperature during operating

-25 .. 70°C

Concurrently switching neutral conductor

Additional equipment possible

Number of poles (total)

1

Connectable conductor cross section solid-core

1 .. 70mm²

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

1 .. 50mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Related products