Aleta.hr
Main Product Image

HMF290

Code: 1761921

ManufacturerHager
Catalog numberHMF290
EAN code3250613231019

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class-
Built-in depth70mm
Release characteristicC
Rated impulse withstand voltage Uimp6kV
Number of poles (total)2
Rated insulation voltage Ui500V
Rated current100A
Rated voltage415V
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Voltage typeAC
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Frequency50 - 60Hz
Additional equipment possibleYes
Power loss16.33W
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Concurrently switching neutral conductorNo
Flush-mounted installationYes
Width in number of modular spacings3
Ambient temperature during operating-25 - 70°C
Over voltage category3
Connectable conductor cross section multi-wired1 - 50mm²
Explosion-proofNo
Connectable conductor cross section solid-core1 - 70mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMF290

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class

-

Built-in depth

70mm

Release characteristic

C

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated current

100A

Rated voltage

415V

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Voltage type

AC

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Frequency

50 .. 60Hz

Additional equipment possible

Power loss

16.33W

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Concurrently switching neutral conductor

Flush-mounted installation

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 70°C

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 50mm²

Explosion-proof

Connectable conductor cross section solid-core

1 .. 70mm²