Aleta.hr
Main Product Image

HMF399

Code: 1761925

ManufacturerHager
Catalog numberHMF399
EAN code3250613231057

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class-
Number of poles (total)3
Number of protected poles3
Rated current125A
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Power loss34.93W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated voltage415V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Built-in depth70mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Over voltage category3
Pollution degree3
Connectable conductor cross section multi-wired1 - 50mm²
Flush-mounted installationYes
Ambient temperature during operating-25 - 70°C
Explosion-proofNo
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1 - 70mm²
Voltage typeAC
Release characteristicC
Width in number of modular spacings4.5
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMF399

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Current limiting class

-

Number of poles (total)

3

Number of protected poles

3

Rated current

125A

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Power loss

34.93W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated voltage

415V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Built-in depth

70mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Over voltage category

3

Pollution degree

3

Connectable conductor cross section multi-wired

1 .. 50mm²

Flush-mounted installation

Ambient temperature during operating

-25 .. 70°C

Explosion-proof

Additional equipment possible

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 70mm²

Voltage type

AC

Release characteristic

C

Width in number of modular spacings

4.5

Degree of protection (IP)

IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.