Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Built-in depth70mm
Voltage typeAC
Explosion-proofNo
Frequency50 - 60Hz
Width in number of modular spacings6
Pollution degree3
Rated voltage415V
Current limiting class3
Over voltage category3
Release characteristicC
Rated current80A
Rated insulation voltage Ui500V
Number of poles (total)4
Additional equipment possibleYes
Power loss25.71W
Connectable conductor cross section multi-wired1 - 50mm²
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Concurrently switching neutral conductorNo
Flush-mounted installationYes
Rated impulse withstand voltage Uimp6kV
Connectable conductor cross section solid-core1 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HMF480

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Built-in depth

70mm

Voltage type

AC

Explosion-proof

Frequency

50 .. 60Hz

Width in number of modular spacings

6

Pollution degree

3

Rated voltage

415V

Current limiting class

3

Over voltage category

3

Release characteristic

C

Rated current

80A

Rated insulation voltage Ui

500V

Number of poles (total)

4

Additional equipment possible

Power loss

25.71W

Connectable conductor cross section multi-wired

1 .. 50mm²

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Concurrently switching neutral conductor

Flush-mounted installation

Rated impulse withstand voltage Uimp

6kV

Connectable conductor cross section solid-core

1 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Related products