Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz40kA
Rated permanent current Iu100A
Rated voltage220 - 415V
Overload release current setting63 - 100A
Adjustment range short-term delayed short-circuit release0 - 0A
Power loss24.8W
Adjustment range undelayed short-circuit release600 - 1300A
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Number of poles3
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
With integrated under voltage releaseNo
Type of control elementToggle
Complete device with protection unitYes
Position of connection for main current circuitFront side
Degree of protection (IP)IP40
Motor drive integratedNo
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HNB100H

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

40kA

Rated permanent current Iu

100A

Rated voltage

220 .. 415V

Overload release current setting

63 .. 100A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Power loss

24.8W

Adjustment range undelayed short-circuit release

600 .. 1300A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Number of poles

3

With switched-off indicator

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Type of control element

Toggle

Complete device with protection unit

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP40

Motor drive integrated

Motor drive optional

Related products