Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Rated voltage220 - 415V
Power loss32.6W
Integrated earth fault protectionNo
Rated permanent current Iu160A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz40kA
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Adjustment range undelayed short-circuit release960 - 2080A
DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting100 - 160A
With switched-off indicatorNo
Number of poles3
With integrated under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Position of connection for main current circuitFront side
Complete device with protection unitYes
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP40
Type of control elementToggle

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HNB160H

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Rated voltage

220 .. 415V

Power loss

32.6W

Integrated earth fault protection

Rated permanent current Iu

160A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

40kA

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Adjustment range undelayed short-circuit release

960 .. 2080A

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

100 .. 160A

With switched-off indicator

Number of poles

3

With integrated under voltage release

Device construction

Built-in device fixed built-in technique

Position of connection for main current circuit

Front side

Complete device with protection unit

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP40

Type of control element

Toggle

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.