  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalYes
Rated permanent current Iu250A
Adjustment range undelayed short-circuit release1250 - 2750A
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz40kA
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP40
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitScrew connection
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release0 - 0A
Rated voltage220 - 415V
With switched-off indicatorNo
Complete device with protection unitYes
Motor drive optionalYes
Overload release current setting160 - 250A
Suitable for DIN rail (top hat rail) mountingNo
Power loss48W
Position of connection for main current circuitFront side
Number of poles4
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HNB251H

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • HAGER

Technical specifications

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Rated permanent current Iu

250A

Adjustment range undelayed short-circuit release

1250 .. 2750A

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

40kA

Device construction

Built-in device fixed built-in technique

Degree of protection (IP)

IP40

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated voltage

220 .. 415V

With switched-off indicator

Complete device with protection unit

Motor drive optional

Overload release current setting

160 .. 250A

Suitable for DIN rail (top hat rail) mounting

Power loss

48W

Position of connection for main current circuit

Front side

Number of poles

4

Motor drive integrated

Related products