Technical specifications

Rated voltage230V
Built-in depth33.5mm
Rated current6A
Release characteristicC
Rated fault current0.01A
Leakage current typeOther
Surge current capacity-kA
Over voltage category-
Connectable conductor cross section solid-core2.5 - 2.5mm²
Number of protected poles1
Pollution degree-
Degree of protection (IP)IP20
Rated insulation voltage Ui-V
With interlocking deviceNo
Connectable conductor cross section multi-wired- - -mm²
Rated short-circuit breaking capacity according to IEC 60947-21.5kA
Current limiting class1
Frequency50/60 Hz
Concurrently switching neutral conductorYes
Width in number of modular spacings43.8
Ambient temperature during operating-5 - 50°C
Rated impulse withstand voltage Uimp-kV
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 61009-11.5kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610091.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

N4305/6 | RCD+MCB 1P+N 6A 10MA 1500A-2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage

230V

Built-in depth

33.5mm

Rated current

6A

Release characteristic

C

Rated fault current

0.01A

Leakage current type

Other

Surge current capacity

-kA

Over voltage category

-

Connectable conductor cross section solid-core

2.5 .. 2.5mm²

Number of protected poles

1

Pollution degree

-

Degree of protection (IP)

IP20

Rated insulation voltage Ui

-V

With interlocking device

Connectable conductor cross section multi-wired

- .. -mm²

Rated short-circuit breaking capacity according to IEC 60947-2

1.5kA

Current limiting class

1

Frequency

50/60 Hz

Concurrently switching neutral conductor

Width in number of modular spacings

43.8

Ambient temperature during operating

-5 .. 50°C

Rated impulse withstand voltage Uimp

-kV

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 61009-1

1.5kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

1.5kA