Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP20
Number of poles4
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu250A
Number of auxiliary contacts as normally open contact0
Overload release current setting150 - 250A
Rated voltage230 - 690V
Number of auxiliary contacts as change-over contact0
Device constructionComplete device in housing
Type of electrical connection of main circuitScrew connection
Motor drive optionalYes
Motor drive integratedNo
Adjustment range undelayed short-circuit release875 - 2500A
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
With under voltage releaseYes
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
With switched-off indicatorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

025349 | DPX 250 4P 250A 36KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Number of poles

4

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

250A

Number of auxiliary contacts as normally open contact

0

Overload release current setting

150 .. 250A

Rated voltage

230 .. 690V

Number of auxiliary contacts as change-over contact

0

Device construction

Complete device in housing

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Motor drive integrated

Adjustment range undelayed short-circuit release

875 .. 2500A

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

With under voltage release

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

With switched-off indicator

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.