Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP20
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu40A
Number of auxiliary contacts as normally open contact0
Overload release current setting24 - 40A
Rated voltage230 - 690V
Number of auxiliary contacts as change-over contact0
Device constructionComplete device in housing
Type of electrical connection of main circuitScrew connection
Motor drive optionalYes
Motor drive integratedNo
Adjustment range undelayed short-circuit release140 - 400A
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
With under voltage releaseYes
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
With switched-off indicatorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

025352 | DPX-H 3P3D 40A 70KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

40A

Number of auxiliary contacts as normally open contact

0

Overload release current setting

24 .. 40A

Rated voltage

230 .. 690V

Number of auxiliary contacts as change-over contact

0

Device construction

Complete device in housing

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Motor drive integrated

Adjustment range undelayed short-circuit release

140 .. 400A

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

With under voltage release

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

With switched-off indicator

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.