Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP20
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu40A
Number of auxiliary contacts as normally open contact0
Overload release current setting16 - 40A
Rated voltage230 - 690V
Device constructionComplete device in housing
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
Motor drive optionalYes
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release- - -A
With under voltage releaseYes
Adjustment range short-term delayed short-circuit release24 - 400A
Position of connection for main current circuitFront side
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
With switched-off indicatorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

025401 | DPX 250 S1 3P 40A 36KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

40A

Number of auxiliary contacts as normally open contact

0

Overload release current setting

16 .. 40A

Rated voltage

230 .. 690V

Device construction

Complete device in housing

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

- .. -A

With under voltage release

Adjustment range short-term delayed short-circuit release

24 .. 400A

Position of connection for main current circuit

Front side

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

With switched-off indicator

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.