Degree of protection (IP)IP20
Number of poles4
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu40A
Number of auxiliary contacts as normally open contact0
Overload release current setting16 - 40A
Device constructionComplete device in housing
Rated voltage230 - 690V
Type of electrical connection of main circuitScrew connection
Motor drive optionalYes
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Adjustment range undelayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseYes
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release24 - 400A
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

025445 | DPX 250 S2 4P 36KA 40A

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Number of poles

4

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

40A

Number of auxiliary contacts as normally open contact

0

Overload release current setting

16 .. 40A

Device construction

Complete device in housing

Rated voltage

230 .. 690V

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Adjustment range undelayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

24 .. 400A

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.