Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP30
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally closed contact1
Rated permanent current Iu20A
Number of auxiliary contacts as normally open contact-
Overload release current setting20 - 20A
Device constructionBuilt-in device fixed built-in technique
Rated voltage110 - 550V
Type of electrical connection of main circuitScrew connection
Motor drive optionalNo
Number of auxiliary contacts as change-over contact1
Motor drive integratedNo
Adjustment range undelayed short-circuit release400 - 400A
Suitable for DIN rail (top hat rail) mountingYes
With under voltage releaseYes
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz10kA
Adjustment range short-term delayed short-circuit release400 - 400A
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

027001 | DRX100 STRUJNI PR. 3P 20A 10KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP30

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

1

Rated permanent current Iu

20A

Number of auxiliary contacts as normally open contact

-

Overload release current setting

20 .. 20A

Device construction

Built-in device fixed built-in technique

Rated voltage

110 .. 550V

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Number of auxiliary contacts as change-over contact

1

Motor drive integrated

Adjustment range undelayed short-circuit release

400 .. 400A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

10kA

Adjustment range short-term delayed short-circuit release

400 .. 400A

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.