Technical specifications

Degree of protection (IP)IP30
Number of poles1
Type of control elementToggle
Number of auxiliary contacts as normally open contact-
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu40A
Motor drive optionalNo
Overload release current setting40 - 40A
Rated voltage110 - 550V
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release400 - 400A
Suitable for DIN rail (top hat rail) mountingYes
With under voltage releaseNo
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release400 - 400A
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

027044 | DRX100 STRUJNI PR. 1P 40A 35KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP30

Number of poles

1

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

40A

Motor drive optional

Overload release current setting

40 .. 40A

Rated voltage

110 .. 550V

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

400 .. 400A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

400 .. 400A

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.