Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current16A
Rated fault current0.03A
Current limiting class-
Release characteristicC
Surge current capacity-kA
Width in number of modular spacings45
Leakage current typeOther
Over voltage category-
Pollution degree-
Rated voltage230V
Rated insulation voltage Ui-V
Built-in depth40mm
Voltage typeAC
Frequency50/60 Hz
Connectable conductor cross section solid-core2.5 - 2.5mm²
Rated short-circuit breaking capacity according to EN 610093kA
With interlocking deviceNo
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity Icn according to EN 61009-13kA
Anti-nuisance tripping versionYes
Number of protected poles1
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-23kA
Number of poles (total)2
Connectable conductor cross section multi-wired- - -mm²
Degree of protection (IP)IP21
Suitable for flush-mounted installationYes
Ambient temperature during operating-5 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

077532 | KZS 16 1P+N 30MA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current

16A

Rated fault current

0.03A

Current limiting class

-

Release characteristic

C

Surge current capacity

-kA

Width in number of modular spacings

45

Leakage current type

Other

Over voltage category

-

Pollution degree

-

Rated voltage

230V

Rated insulation voltage Ui

-V

Built-in depth

40mm

Voltage type

AC

Frequency

50/60 Hz

Connectable conductor cross section solid-core

2.5 .. 2.5mm²

Rated short-circuit breaking capacity according to EN 61009

3kA

With interlocking device

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

3kA

Anti-nuisance tripping version

Number of protected poles

1

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

3kA

Number of poles (total)

2

Connectable conductor cross section multi-wired

- .. -mm²

Degree of protection (IP)

IP21

Suitable for flush-mounted installation

Ambient temperature during operating

-5 .. 40°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.