Aleta.hr
Main Product Image

336904 | KABEL (200M KOTUR)

Code: 1777062

ManufacturerLegrand
Catalog number336904
TypeCables
EAN code8012199654362

















Details

  • Cables
  • Power cable < 1 kV, for permanent installation
  • 1 KOM
  • LEGRAND

Technical specifications

Oil resistant (according to EN 60811-404)No
Min. permitted bending radius, stationary application/permanent installation-mm
Low temperature resistant (according to EN 60811-504+505+506)No
Nominal cross section conductor (AWG)-kcmil
Twisted coresNo
Diameter conductor1.7mm
Conductor materialCopper
Material core insulationOther
With protective conductorNo
Core identificationColour
Nominal cross section conductor0.5mm²
Armouring/reinforcementNone
Max. conductor temperature70°C
Material outer sheathPolyvinyl chloride (PVC)
Protective barrierNone
Low smoke (according to IEC 61034-2)No
Colour outer sheathWhite
Permitted cable outer temperature during assembling/handling-15 - 70°C
Permitted cable outer temperature after assembling without vibration-15 - 70°C
Conductor categoryClass 2 = stranded
Drain wireNo
Nominal voltage U400V
Outer diameter approx.4.8mm
ScreenNo
Number of cores2
Nominal voltage U00V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

336904 | KABEL (200M KOTUR)

Main Product Image

Details

  • Cables
  • Power cable < 1 kV, for permanent installation
  • 1 KOM
  • LEGRAND

Technical specifications

Oil resistant (according to EN 60811-404)

Min. permitted bending radius, stationary application/permanent installation

-mm

Low temperature resistant (according to EN 60811-504+505+506)

Nominal cross section conductor (AWG)

-kcmil

Twisted cores

Diameter conductor

1.7mm

Conductor material

Copper

Material core insulation

Other

With protective conductor

Core identification

Colour

Nominal cross section conductor

0.5mm²

Armouring/reinforcement

None

Max. conductor temperature

70°C

Material outer sheath

Polyvinyl chloride (PVC)

Protective barrier

None

Low smoke (according to IEC 61034-2)

Colour outer sheath

White

Permitted cable outer temperature during assembling/handling

-15 .. 70°C

Permitted cable outer temperature after assembling without vibration

-15 .. 70°C

Conductor category

Class 2 = stranded

Drain wire

Nominal voltage U

400V

Outer diameter approx.

4.8mm

Screen

Number of cores

2

Nominal voltage U0

0V

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.